Hey Oak forest, IL: need a new central air conditioning system, or need help with your existing system? We are air conditioning experts and can help you decide what is you best cooling system option. At B&B Heating & Cooling, Inc., we install and service all types and brands of air conditioning. So contact us today. We offer prompt knowledgable advice for your Oak forest, IL home or business.


Upon arrival the Tech. found the Tapan Furnace was not working properly due to a low flame signal. Cleaned the furnace and flame sensor, the unit was fully oeprational at departure.

Oak Forest, IL
03-21-2019


Upon arrival Tech, found the furnace not operating properly due to a dirty flame sensor and clogged condensate drain. Cleaned the furnace and purged C02 through drain.

Oak Forest, IL
03-22-2019


Upon arrival the Tech. found some duct supply takes are coming apart or disconnected. Main supply trunk is rotted out badly as it comes thru the concrete foundation. Needs to be re-fabricated, furnace needs to come out to rebuild ducting into crawl spaces.

Oak Forest, IL
05-15-2019


Upon arrival the Tech. found the cast iron baseboard radiator deteriorated, the Dunkirk Boiler had no pressure. The Cast Iron base board, Radiator Valve Pressure Reducing Valve and the Expansion Tank needs replacement.

Oak Forest, IL
05-15-2019


Upon arrival the Tech. found the cast iron baseboard radiator deteriorated, the Dunkirk Boiler had no pressure. The Cast Iron base board, Radiator Valve Pressure Reducing Valve and the Expansion Tank needs replacement.

Oak Forest, IL
05-15-2019

Airease Heating & Cooling 4SCU13LE160P-5
Upon arrival the Tech. found the furnace not working due to a low flame signal. Cleaned the furnace and flame sensor. The furnace was fully operational at departure.
Oak Forest, IL
05-15-2019

4SCU13LE160P-5
Conducted Spring Preventative Maintenance. Checked refrigerant levels, electrical components and cleaned the condenser.

Oak Forest, IL
05-22-2019

starstarstarstarstar
5 Star Rating
Rheem 13AJA30
Conducted Spring PM on one Rheem unit. Inspected refrigerant levels and electrical components and cleaned condenser. AC fully operational at departure.
Oak Forest, IL
06-27-2019

13AJA30
Upon arrival the Tech. found the Lennox AC system from 2014 not operating due to the AC system freezing up. Thawed the system. Performed Leak Check and found no leaks. Added 1-1/2 lbs. of R410A. The system was fully operational at departure.

Oak Forest, IL
07-09-2019

13AJA30
Upon arrival the Tech. found the Lennox AC system from 2014 not operating due to low refrigerant levels. Performed leak check and added 1-1/2 Lbs. of R-410A refrigerant. The system was fully operational at departure.

Oak Forest, IL
07-09-2019

Lennox XC14-042 14 SEER Air Conditioner
Upon arrival the Tech. found the Lennox furnace fully operational. Investigated where the water was coming and waste water from house wasn’t draining because sump pump was unplugged. Resident stated someone from another company came out and did some work on their AC. Plugged sump pump in and water started draining properly.
Oak Forest, IL
07-10-2019

XC14-042
Upon arrival the Tech. found the Condensate Drain disconnected causing water to leak on the floor. Properly connected drain. Checked refrigerant levels and discovered the system was low on R-410A refrigerant. Charged system with 2 pounds of R-410A refrigerant. Conducted an electronic test and found no leaks. The AC system was fully operational at departure.

Oak Forest, IL
07-23-2019

XC14-042
Upon arrival the Tech. found the AC system not operating due to a blown capacitor. Replaced the 45/5 µF capacitor and cleaned the condenser.The AC system was fully operational at departure.

Oak Forest, IL
07-31-2019

XC14-042
Upon arrival the Tech. found the Carrier AC System from 2013 was not operating due to a faulty TXV (Expansion Valve). The TXV will need to be replaced, the System will then be Pressure Tested, Pumped into a Vacuum, and the Charge will be confirmed. Per the Carrier Distributor, the TXV is no longer under warranty. Expired Dec. 2018.

Oak Forest, IL
08-05-2019

XC14-042
Upon arrival the Tech. found the Carrier AC System from 2013 was not operating due to a faulty TXV (Expansion Valve). The TXV will need to be replaced, the System will then be Pressure Tested, Pumped into a Vacuum, and the Charge will be confirmed. Per the Carrier Distributor, the TXV is no longer under warranty. Expired Dec. 2018.

Oak Forest, IL
08-05-2019

XC14-042
Complaint of the AC not cooling. - The Leak has been located in the outside Condenser Coil and cannot be repaired. - A Leak was also located at the A-Coil, and will need to be repaired. The following is the proposal to replace the

Oak Forest, IL
08-05-2019

Lennox 13ACX-036
Upon arrival the Tech. found the Lennox AC system from 2014 not operating properly due to the furnace door not making contact with the door switch. Properly secured furnace door to make contact with the door switch. Checked refrigerant, and system was low on R410A refrigerant. Added 3 lbs. of R410A refrigerant. Also, Chemically Cleaned the Condenser. The AC was fully operational at departure.
Oak Forest, IL
08-12-2019

Carrier 24ABB336
Upon arrival the Tech. found the Carrier AC system from 2014 not operating properly due to a faulty Capacitor. Replaced the 45+5 Capacitor and ran the system. The AC was fully operational at departure.
Oak Forest, IL
09-18-2019

Lennox 13ACX-036
Upon arrival the Tech. found the Lennox R410A AC System from 2014 was not working due to having Low Refrigerant in the AC System. An Electronic Leak Test was performed, and leaks were found at both the A-Coil & Condenser. * After checking with the Manufacturer we found both Condenser & A-Coil are beyond the 5-Year Warranty, therefore, we recommend replacement with a Lennox 3-Ton 13 SEER (R410A) Condenser, a matched 3-Ton A-Coil, and, Set the Condenser on the existing AC Pad, then Pressure Test, Pump into Vacuum, and Check that the AC System is at Manufacturers Refrigerant Specification.
Oak Forest, IL
09-18-2019