Summertime temperatures leaving you hot under the collar? In Plainfield, IL the vast majority of homes have some sort of system to keep those indoor temperatures down in the summer. At B&B Heating & Cooling, Inc. we are residential comfort specialists. Installing or replacing central air can be a significant project, so youll want to get it right. Our expert air conditioner techs can evaluate you system and your needs and recommend a course of action thats best for you.


Upon arrival the Tech found the Tappen Furnace operating but the circuit board was not wired properly. Corrected witing to circuit board ant furnace. Cl;eaned Furnace and Flame Sensor. AC was running at the same tome as furnace due to a bad 40 amp contactor on AC condenser - Repalced Contactor. The Unit was fully operational at departure.

Plainfield, IL
03-22-2019


Upon arrival the Techh. found the Bryant furnace from 2004 ws inoperable due to a faulty Ignitor and a low flame signal. Replace the Igniter and cleaned the furnace and flame sensor, the unit was fully operational at departure.

Plainfield, IL
03-22-2019


Cleaned furnace

Plainfield, IL
03-22-2019


Upon arrival the Tech. found the Goodman furnace not igniting. Found a faulty HSI. The HSI needed to be replaced.Also there was a low flame signal - Cleaned the Furance and Flame Sensor.

Plainfield, IL
03-25-2019


Low Pressure swtich stuck open

Plainfield, IL
05-29-2019

Lennox 13ACX-042
Upon arrival the Tech. found the International Comfort Products R22 AC System from 2004 is completely out of refrigerant.
Plainfield, IL
06-12-2019

13ACX-042
Upon arrival the Tech. found the furnace fully operational and found the Tappan AC System from 2002 inoperable due to a faulty capacitor and 2-wire incorrectly wired. Replaced the 45+5 capacitor and rewired the low voltage 2-wire. This fixed the problem with the heating and cooling operating simultaneously. The AC system was fully operational at departure.

Plainfield, IL
07-10-2019

13ACX-042
Upon arrival the Tech. found the American Standard AC system not operating properly due to a Shorted Contactor. Replaced the Contactor and Chemically cleaned the Condenser. The AC System was fully operational at departure.

Plainfield, IL
07-29-2019

13ACX-042
Upon arrival the Tech. found the Goodman AC system not operating properly due to a blown capacitor. Replaced the 55/5 µF capacitor and cycled the unit. The AC system was fully operational at departure.

Plainfield, IL
07-31-2019

13ACX-042
Upon arrival the Tech. found the Tempstar AC system from 2011 was empty of R410A Refrigerant. An Electronic Leak Check was performed after adding 1 Lb. R410A Refrigerant to allow for the test. Multiple leaks were located at the A-Coil, and the Schrader Valves were leaking at the Condenser. Replacement of the entire AC System as follows is one option, however, at a minimum, the A-Coil will need replacement along with the Schrader Valves on the Condensing Unit, and then, the AC system will need to be Pressure Tested, Pumped into a Vacuum, and re-charged with R410A Refrigerant as per Manufacturers Specification.

Plainfield, IL
08-06-2019

13ACX-042
Upon arrival the Tech. found the Tempstar AC system from 2011 was empty of R410A Refrigerant. An Electronic Leak Check was performed after adding 1 Lb. R410A Refrigerant to allow for the test. Multiple leaks were located at the A-Coil, and the Schrader Valves were leaking at the Condenser. Replacement of the entire AC System as follows is one option, however, at a minimum, the A-Coil will need replacement along with the Schrader Valves on the Condensing Unit, and then, the AC system will need to be Pressure Tested, Pumped into a Vacuum, and re-charged with R410A Refrigerant as per Manufacturers Specification.

Plainfield, IL
08-06-2019

York HVAC H2RD048S
Upon arrival the Tech. found the York R22 AC System not working due to a bad Compressor. Recommend replacement. - Vendor quote rejected.
Plainfield, IL
08-09-2019

H2RD048S
Upon arrival the Tech. found the York R22 AC System from 2002 was not operating due to being low on R22 Refrigerant. - R22 Refrigerant was added to the System to allow a Electronic Leak Test to be performed. - The Electronic Leak Test detected leaks at both Condenser & A-Coil. 7/5/19 Per George Bellows at IH, we returned to the property to charge the system with the hope that the AC System would make it through the 2019 AC Season. 3 Lbs. of R22 were added to the existing York AC System from 2002. (THIS WORK HAS ALREADY BEEN COMPLETED!)

Plainfield, IL
08-12-2019

H2RD048S
Upon arrival the Tech. found the Trane system inoperable due to a burnt wire and a faulty capacitor. Repaired the 2-wire and replaced the capacitor. The AC system was fully operational at departure.

Plainfield, IL
08-12-2019

H2RD048S
Upon arrival the Tech. found the Ac system not operating properly due to a fauly capacitor. Replaced the 45+5 Capacitor. The AC system was fully operational at departure.

Plainfield, IL
08-16-2019

H2RD048S
Upon arrival the Tech. found the AC system not operating properly due to a faulty capacitor. Replaced the 35+5 Capacitor. The AC system was fully operational at departure.

Plainfield, IL
08-16-2019

H2RD048S
Upon arrival the Tech. found the AC system fully operational. The resident had the Thermostat set to 60 degrees and it was 70 degrees in the house. The Tech. informed the resident that the system can only do a 15-20 degree difference from what the temperature is outside. The AC was fully operational at departure

Plainfield, IL
08-16-2019

Lennox 13ACX-048
Upon arrival the Tech. found the Carrier R22 AC System from 2001 was not working due to a bad Compressor. Although it appears the Capacitor was recently replaced, and a Hard Start Kit had been installed, the Compressor won't stay running and is making alot of noise. * Based upon both Age as well as the System being an R22 System we recommend replacement with a Lennox 4-Ton 13 SEER (R410A) Condenser, a matched 4-Ton A-Coil, Fabricate and Install a Custom Sheet Metal Transition to accommodate the new A-Coil, Flush the existing refrigerant lines, Replace the Electrical Whip at the New AC Condenser, Set the Condenser on the existing AC Pad, and Pressure Test, Pump into Vacuum, and Check that the AC System is at Manufacturers Refrigerant Specification.
Plainfield, IL
09-16-2019

American Standard HVAC 7A0036A1000
Upon arrival the Tech. found the AC system not operating due to low refrigerant levels. Added 2lbs. of R-22 Refrigerant. The AC was fully operational at departure. received phone approval for $302.56 from George Bellows @ IH per phone onsite NTE increase request from tech Steven @ Affiliate. Bruce Kniffin/SME-HVAC
Plainfield, IL
09-20-2019

Lennox 13ACX-036
Upon arrival the Tech. found the Lennox AC system not operating properly due to low refrigerant levels. The Tech. added 1lb. of R-410A. The AC was fully operational at departure.
Plainfield, IL