B&B Heating & Cooling, Inc. specializes in installation and replacement of all types of gas furnaces in Plainfield, IL. We offer a wide variety of gas furnace installation and gas furnace replacement options to meet efficiency and budget needs. Our staff can diagnosis your existing systems and recommend terrific new high efficiency choices. We offer same day evaluation and prompt gas furnace installation services in Plainfield, IL.

Let us help you decide how best to solve you gas heating problems the the installation or replacement of a gas furnace.

Goodman GMS81205D
Weak flame signal .3ua then drops out. Cleaned furnace now 2.7ua. Checked inducer port
Plainfield, IL
03-15-2019

Lennox G40UH-48C-110
Cleaned furnace and flame sensor. Replaced gas valve
Plainfield, IL
03-15-2019

Lennox ML180UH090P36B
Upon arrival the Tech. found the Lennox furnace from 2015 was not working properly due to a llow flame signal. cleaned the furnace and flame sensor. The unit was fully operational at departure.
Plainfield, IL
03-25-2019

Goodman GMH81005C
Upon arrival the Tech. found the Goodman Furnace was inoperabledue to a faulty pressure swotch and a low flame signal. Replaced pressure switch and cleaned the flame sensor and furnace. The unit was fully operational at the time of departure.
Plainfield, IL
03-25-2019

Lennox ML180UH070P36A
Upon arrival the Tech. found the Lennox furnace from 2015 not working properly due to a blocked Inducer port. Cleared the Inducer port and cleaned the Furnace and flame sensor. The Furnace was fully operational at departure.
Plainfield, IL
03-25-2019

Goodman GMS81005C
Upon arrival the Tech. found the Goodman furnace was not operating properly due to a low flame signal. Cleaned the Furnace and Flame Sensor. The furnace was fully operational.
Plainfield, IL
03-25-2019

Lennox G40UH-48C-110
Upon arrival the Tech. found the Lennox Furnace from 2004 was in operable due to a low Flame Signal. Cleaned the Furnace and Flame Sensor. The unit was fully operational at departure.
Plainfield, IL
04-03-2019

Lennox ML180UH110P48C
Upon arrival the Tech. found the Lennox Furnace from 2014 not working properly due to a low flame signal. Cleaned the Furnace and Flame Sensor, the unit was fully operational at departure.
Plainfield, IL
04-09-2019

Goodman GMH80603A
Upon arrival the Tech. found that there was a new filter that had been sucked into the the Blower Wheel . After removal of the Filter, the Furnace still has a slight vibration. The AC System is cooling properly, but the Blower Wheel needs to be replaced. The Blower Wheel should be to replace on the Furnace. Please note that the Wheel is not covered under a Parts Warranty as the Goodman Warranty is only valid for the installing homeowner. If we don't know the correct name of that person, it will not be covered under the warranty.
Plainfield, IL